PRJ-3448 | Advanced High Strength Cold-Formed Steel Coupon Tests at Ambient, Elevated, and Subzero Temperatures
PI
Co-PIs; ;
Project TypeExperimental
Natural Hazard Type(s)Extreme Temperatures
Awards
Optimization and Application of Next Generation Steels in Construction | 1760953
KeywordsTensile coupon test data, elevated temperatures, postfire, subzero temperatures
Version
2
|
Description:

Tensile coupon test data for advanced high-strength cold-formed steel subjected to ambient, elevated, and subzero temperatures.

Experiment | Tensile coupon tests of advanced high-strength cold-formed steel alloys at subzero temperatures
Cite This Data:
Xia, Y., H. Blum (2023). "Tensile coupon tests of advanced high-strength cold-formed steel alloys at subzero temperatures", in Advanced High Strength Cold-Formed Steel Coupon Tests at Ambient, Elevated, and Subzero Temperatures [Version 2]. DesignSafe-CI. https://doi.org/10.17603/ds2-my6x-6e21

Experiment | Tensile coupon tests of advanced high-strength cold-formed steel alloys
Cite This Data:
Xia, Y., C. Ding, Z. LI, B. Schafer, H. Blum (2023). "Tensile coupon tests of advanced high-strength cold-formed steel alloys", in Advanced High Strength Cold-Formed Steel Coupon Tests at Ambient, Elevated, and Subzero Temperatures [Version 2]. DesignSafe-CI. https://doi.org/10.17603/ds2-wfee-4j83

Experiment | Tensile coupon tests of advanced high-strength cold-formed steel alloys at elevated temperatures and after cooling down
Cite This Data:
Xia, Y., X. Yan, T. Gernay, H. Blum (2023). "Tensile coupon tests of advanced high-strength cold-formed steel alloys at elevated temperatures and after cooling down", in Advanced High Strength Cold-Formed Steel Coupon Tests at Ambient, Elevated, and Subzero Temperatures [Version 2]. DesignSafe-CI. https://doi.org/10.17603/ds2-f6k8-5d67